Elation 5R Dokumentacja Strona 49

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 60
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 48
Platinum Spot 5R Pro™
©Elation Professional, Los Angeles, Ca 49 www.ElationLighting.com
defective motor IC drive on the main PCB).
Color-wheel error:
The color wheel is not located in the default position after start-up or after a reset
command.This message will appear after a fixture reset if the color wheel’s
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or a defective motor IC drive on the main PCB).
Rotating gobo-wheel error:
The gobo-wheel is not located in the default position after start-up or after a reset
command.This message will appear after a fixture reset if the gobo wheel’s
magnetic-indexing circuit malfunctions (sensor failed or magnet is missing) or there is a
stepper motor failure (defective motor or a defective motor IC drive on the main PCB).
Rotating gobo indexing error:
The gobo is not located in the default position after start-up or after a reset command.This
message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
Fix Gobo-wheel error:
This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
drive circuit on the main PCB). The fix gobo wheel is not located in the default position after
the reset.
Prism Rotation error:
This message will appear after the reset of the fixture and if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its
driver circuit on the main PCB). The Prism wheel is not located in the default position after
the reset.
Focus-error:
This message will appear after the reset of the fixture and if the magnetic indexingcircuit